The Electrostat ES3 is a handheld Static Electricity Meter (also known as a Static Charge Meter) with very high sensitivity and resolution down to 0.001kV (1 Volt). It is calibrated to be held 1” (25 mm) from the test surface (measures without contact); and comes with a non conductive magnetically attached spacer that positions the sensor at the calibrated distance.
The ES3 can detect even a 1 volt charge anywhere within its full range of +29,999 to -29,999 volts, making it very easy to measure whether a given process is increasing or decreasing the static electricity present; even if the increase or decrease is by a tiny fraction.
The static signal is read and updated on the screen 4 times per second, and the highest positive and highest negative signals are captured and stored. You can clear the Peak-hold data by pressing the “Peak Reset” button at any time to start a new data set. The peak function has a capture window of 0.005 seconds (which is much faster than the display) so even very quick peaks are captured and stored. The alarm function is can be configured by the user to sound if the signal (+ or -) ever exceeds the value set by the user for at least 0.005 seconds. The alarm can be reset or muted at any time, and there are also visual cues of alarm status on the screen.
Electrostat ES3 Features:
- 3.2″ IPS Touchscreen with adjustable brightness and light/dark modes for any viewing environment.
- USB C port:
- Supports charging the internal battery from any USB host device or USB charger.
- Data transfer into our all new PC application (available Q2 2024).
- Firmware is also updateable through the PC application (when updates are available).
- Detachable probe allowing for easy repair/replacement; and the platform will also support new probe designs as they are released. Device support for new probes will be updated through firmware updates.
- On screen data plot with adjustable time-base and range control (or autorange). The data plot can also be configured as a signal strength bar.
- 1/8″ Analog output jack calibrated to +/-2.5V = +/-25kV. (The output jack is limited to +/-25kV though the ES3 can display up to +/-30kV)
- Inactivity Timer for Auto power down. Can be set up for 15/30/60 minutes, or disabled. The timer resets anytime the screen or a button is touched.
- 3 Different Alarm Modes:
- Visual only: Display indicates alarm level exceeded, audio is muted.
- Variable pitch: Alarm starts at 1/10 entered alarm level, and the pitch changes with the input signal up to the alarm level.